Add to Cart
Household energy storage system, also known as household energy storage system, is similar to a micro energy storage power station, and its operation is not affected by urban power supply pressure. During the low power consumption time, the battery pack in the household energy storage system can be charged by itself for use during the peak or power outage. In addition to being used as emergency power supply, the household energy storage system can also balance the power load, thus saving household power expenditure.
At present, the home energy storage system is mainly combined with photovoltaic, forming a hybrid, coupled, off grid and other home photovoltaic+energy storage systems.
Feature :
Specifications:
No | Item | General Parameter | Remark | |
1 | Combination method | 16S1P | ||
2 | Rated Capacity | Typical | 100Ah | Standard discharge after Standard charge(package) |
Minimum | 98Ah | |||
3 | Factory Voltage | 50V-53V | Mean Operation Voltage | |
6 | Internal Impedance | ≤40 mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test | |
7 | Max Charging Current(Icm) | 100A | Ampere-meter ,Maximum allowable charging current of the battery pack | |
8 | Limited Charging Voltage(Ucl) | 58.4V | Volta-meter (Serial*3.65V) ,Battery pack safe charging voltage | |
9 | Max Discharging current | 100A | Maximum discharge current allowed by the battery pack | |
10 | Discharge Cut-off voltage(Udo) | 44.8V | Voltage of the battery when the discharge is stopped | |
11 | Operation Temperature Range | Charge:0~55℃ | Charge | |
Discharge: -20~60℃ | Discharge | |||
12 | Storage Temperature Range | Less than 12 months : -10~35℃ | Recommend(25±3℃);≤60±25%RH storage moisture range. | |
less than 3 months: -10~45℃ | ||||
Less than 7 day : -20~55℃ | ||||
13 | Single module Size/weight | 680*500*160mm | 1PCS,Single mode group approx: 50kg±5% | |
6.3.1 Battery Management System | ||||
A:BMS function introduction | ||||
1 overcharge detection function | ||||
2 over discharge detection function | ||||
3 over current detection function | ||||
4 short detection function | ||||
5 Temperature detection function | ||||
6 balance function | ||||
7 communicate function | ||||
8 Alarm function | ||||
9 Total capacity function | ||||
10 Storage history function |
Product Details :
Applications: